80 resultados para Reproducibility of Results

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This study examined whether patellar tendon vascularity could be quantified accurately in the clinical setting using colour Doppler ultrasonography.

Methods: A sonographer and two radiologists visually estimated tendon vascularity in millimetres in 74 tendons during ultrasound (US) examination and from hard copy films. These estimates were then compared to the length of vessels measured from the digital image in millimetres and the correlation between them was determined. A subset of 16 tendons was used to compare the estimates of vascularity by two examiners at US examination.

Results: The estimation of vascular length at US examination correlated highly with the measured vascular length (r = 0.92; 95% confidence interval (CI) 0.87 to 0.94), as did the length estimated from the films (r = 0.94; 95% CI 0.9 to 0.96). The correlation between examiners was 0.84 (95% CI 0.51 to 0.94) for the estimates made during US examination and 0.85 (95% CI 0.59 to 0.95) for the vessel lengths measured from the digital images.

Conclusions: These excellent correlations indicate that tendon vascularity can be reliably estimated using colour Doppler ultrasonography and tendon vascularity could therefore be used by clinicians to rate clinical change. This method of quantifying tendon vascularity could also be used in research to investigate the effects of tendon treatments on vascularity.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aortic pulse wave velocity (aPWV), a noninvasive measure of vascular stiffness, is an independent predictor of cardiovascular disease both before and in overt vascular disease. Its characteristics in early life and its relationship to maternal factors have hardly been studied. To test the hypothesis that infant aPWV was positively related to maternal anthropometry and blood pressure (BP) at 28 weeks gestation, after adjusting for neonatal anthropometry and BP, 148 babies born in Manchester were measured 1 to 3 days after birth. A high reproducibility of aPWV, assessed in 30 babies within 3 days of birth, was found with a mean difference between occasions of –0.04 m/s (95% CI: –0.08 to 0.16 m/s). Contrary to our hypothesis, a significant inverse relation was found between neonatal aPWV (mean: 4.6 m/s) and maternal systolic BP (mean: 108.9 mm Hg; r=–0.57; 95% CI: –0.67 to –0.45) but not maternal height nor weight. Neonatal aPWV was positively correlated with birth length, birth weight, and systolic BP. In multiple regression, neonatal aPWV remained significantly inversely associated with maternal systolic BP (adjusted ß coefficient: –0.032; 95% CI: –0.040 to –0.024; P<0.001), after adjustment for maternal age, birth weight, length, and neonatal BP (all independently and positively related to aPWV) and for gestational age, maternal weight, and height (unrelated). These results suggest that infant aPWV may be a useful index of infant vascular status, is less disturbing to measure than infant BP, and is sensitive to the gestational environment marked by maternal BP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The prognosis for patients with localized primary cutaneous melanoma is known to depend principally on tumor thickness, and to a lesser extent on ulcerative state and Clark level. We have recently found in an analysis of 3661 patients that tumor mitotic rate (TMR) is also an important prognostic parameter, ranking second only to tumor thickness. However, few studies have assessed the accuracy and reproducibility with which these features of a melanoma are recorded by histopathologists.
Aim: To assess interobserver reproducibility of major pathologic prognostic parameters in cutaneous melanoma.
Methods: Single hematoxylin and eosin-stained slides of 69 dermally invasive primary cutaneous melanomas were circulated among six pathologists with differing experience in the assessment of melanocytic tumors. The observers independently determined the tumor thickness, Clark level of invasion, ulcerative state, and TMR for each lesion. Intraclass correlation coefficients and kappa scores for multiple ratings per subject were calculated.
Results: The intraclass correlation coefficients were 0.96 for tumor thickness and 0.76 for TMR. The kappa scores were 0.83 for ulcerative state and 0.60 for Clark level. These results indicated excellent agreement among the pathologists for measurements of tumor thickness, ulcerative state, and TMR and fair to good agreement for Clark level.
Conclusions: Appropriately trained and experienced histopathologists can assess prognostically important features of melanomas accurately and reproducibly. Given our recent finding of the significance of TMR in determining prognosis, it is important that this feature be assessed by a standardized method and documented for all primary cutaneous melanomas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Aortic intima-media thickness measured by transabdominal ultrasound (aIMT) is an intermediate phenotype of cardiovascular risk. We aimed to (1) investigate the reproducibility of aIMT in a population-derived cohort of infants; (2) establish the distribution of aIMT in early infancy; (3) compare measurement by edge-detection software to that by manual sonographic calipers; and (4) assess the effect of individual and environmental variables on image quality. Methods. Participants were term infants recruited to a population-derived birth cohort study. Transabdominal ultrasound was performed at six weeks of age by one of two trained operators. Thirty participants had ultrasounds performed by both operators on the same day. Data were collected on environmental (infant sleeping, presence of a sibling, use of sucrose, timing during study visit) and individual (post-conception age, weight, gender) variables. Two readers assessed image quality and measured aIMT by edge-detection software and a subset by manual sonographic calipers. Measurements were repeated by the same reader and between readers to obtain intra-observer and inter-observer reliability. Results: Aortic IMT was measured successfully using edge-detection in 814 infants, and 290 of these infants also had aIMT measured using manual sonographic calipers. The intra-reader intra-class correlation (ICC) (n = 20) was 0.90 (95% CI 0.76, 0.96), mean difference 1.5 μm (95% LOA -39, 59). The between reader ICC using edge-detection (n = 20) was 0.92 (95% CI 0.82, 0.97) mean difference 2 μm (95% LOA -45.0, 49.0) and with manual caliper measurement (n = 290) the ICC was 0.84 (95% CI 0.80, 0.87) mean difference 5 μm (95% LOA -51.8, 61.8). Edge-detection measurements were greater than those from manual sonographic calipers (mean aIMT 618 μm (50) versus mean aIMT 563 μm (49) respectively; p < 0.001, mean difference 44 μm, 95% LOA -54, 142). With the exception of infant crying (p = 0.001), no associations were observed between individual and environmental variables and image quality. Conclusion: In a population-derived cohort of term infants, aIMT measurement has a high level of intra and inter-reader reproducibility. Measurement of aIMT using edge-detection software gives higher inter-reader ICC than manual sonographic calipers. Image quality is not substantially affected by individual and environmental factors. © 2014 McCloskey et al.; licensee BioMed Central Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Accurate dietary assessment is key to understanding nutrition-related outcomes and is essential for estimating dietary change in nutrition-based interventions. OBJECTIVE: The objective of this study was to assess the pan-European reproducibility of the Food4Me food-frequency questionnaire (FFQ) in assessing the habitual diet of adults. METHODS: Participants from the Food4Me study, a 6-mo, Internet-based, randomized controlled trial of personalized nutrition conducted in the United Kingdom, Ireland, Spain, Netherlands, Germany, Greece, and Poland, were included. Screening and baseline data (both collected before commencement of the intervention) were used in the present analyses, and participants were included only if they completed FFQs at screening and at baseline within a 1-mo timeframe before the commencement of the intervention. Sociodemographic (e.g., sex and country) and lifestyle [e.g., body mass index (BMI, in kg/m(2)) and physical activity] characteristics were collected. Linear regression, correlation coefficients, concordance (percentage) in quartile classification, and Bland-Altman plots for daily intakes were used to assess reproducibility. RESULTS: In total, 567 participants (59% female), with a mean ± SD age of 38.7 ± 13.4 y and BMI of 25.4 ± 4.8, completed both FFQs within 1 mo (mean ± SD: 19.2 ± 6.2 d). Exact plus adjacent classification of total energy intake in participants was highest in Ireland (94%) and lowest in Poland (81%). Spearman correlation coefficients (ρ) in total energy intake between FFQs ranged from 0.50 for obese participants to 0.68 and 0.60 in normal-weight and overweight participants, respectively. Bland-Altman plots showed a mean difference between FFQs of 210 kcal/d, with the agreement deteriorating as energy intakes increased. There was little variation in reproducibility of total energy intakes between sex and age groups. CONCLUSIONS: The online Food4Me FFQ was shown to be reproducible across 7 European countries when administered within a 1-mo period to a large number of participants. The results support the utility of the online Food4Me FFQ as a reproducible tool across multiple European populations. This trial was registered at clinicaltrials.gov as NCT01530139.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

New communications technologies often allow new ways of conducting market research. Determining the advantages of a new data collection method over established alternatives is difficult without thorough comparative testing. Computer-mediated marketing research is one such example of a new technology that has been enthusiastically embraced by marketing organisations and those servicing them. While researchers using the Internet (Net) and World Wide Web (Web) in its early years reported benefits such as high response levels, there is little in the way of comparative evidence to support any claimed advantages. This paper reports on the outcomes of three separate studies in which members (subscribers) of various organisations have been surveyed using both postal and online (email invitation and HTML Web form) data collection methods. The conclusion here is that it would be unwise to assume that one method can be directly substituted for another and obtain the same response. Differences in both the response pattern and demographic profile of respondents between the groups are consistently noticed, such as to warrant further examination of the methods used in online marketing research, and to suggest the need for further study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background
The purpose of this study was to examine the reliability of stage of change (SOC) measures for moderate-intensity and vigorous physical activity in two separate samples of young adults. Staging measures have focused on vigorous exercise, but current public health guidelines emphasize moderate-intensity activity.
Method
For college students in the USA (n = 105) and in Australia (n = 123), SOC was assessed separately on two occasions for moderate-intensity activity and for vigorous activity. Test–retest repeatability was determined, using Cohen’s kappa coefficient.
Results
In both samples, the reliability scores for the moderate-intensity physical activity staging measure were lower than the scores for the vigorous exercise staging measure. Weighted kappa values for the moderate-intensity staging measure were in the “fair to good” range for both studies (0.50 and 0.45); for the vigorous staging measure kappa values were “excellent” and “fair to good” (0.76 and 0.72).
Conclusions
There is a need to standardize and improve methods for staging moderate-intensity activity, given that such measures are used in public health interventions targeting HEPA (health-enhancing physical activity).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a three-component model of a digital investigation which comprises: determination of input-output layers, assignment of read and write operations associated with use of forensic tools, and time-stamping of read and write operations. This builds on work of several authors, culminating in the new model presented here which is generic, scalable and compatible with all functions in the system, and which is guaranteed to produce a high quality of reproducibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Overweight and obesity rates among children in Australia have increased twofold in the last decade. Physical activity is thought to play an important role in the prevention and treatment of childhood obesity. Children's physical activity data in Australia are incomplete and mainly based on parental proxy reports. One of the reasons for the lack of children's physical activity prevalence data in Australia is the difficulties of measurement. The aim of this study was to develop and examine a reliable, valid and feasible method for assessing physical activity among primary school aged children. A total of 112 grade 5 and 6 children and their parents were recruited from four state primary schools in the eastern and western suburbs of Melbourne. The test-retest reliability of a parental proxy physical activity questionnaire and a children's self report physical activity questionnaire was assessed. The criterion validity of the questionnaires was assessed using accelerometry. Findings suggest that the self report and proxy report questionnaires provided reliable measures of the type, frequency and duration of children's physical activity behaviour. Overall, the criterion validity of the questionnaires was poor. Although accelerometry as an objective measure shows promise, it does not provide the important physical activity behavioural and contextual information that is critical for the development of strategies to promote physical activity among children. We recommend that a combination of self report or proxy and objective measurement (using accelerometry or even pedometry) appears to be the current 'best buy' in the assessment of children's physical activity behaviour.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The diagnosis of displacement in scaphoid fractures is notorious for poor interobserver reliability.

Questions/purposes We tested whether training can improve interobserver reliability and sensitivity, specificity, and accuracy for the diagnosis of scaphoid fracture displacement on radiographs and CT scans.

Methods Sixty-four orthopaedic surgeons rated a set of radiographs and CT scans of 10 displaced and 10 nondisplaced scaphoid fractures for the presence of displacement, using a web-based rating application. Before rating, observers were randomized to a training group (34 observers) and a nontraining group (30 observers). The training group received an online training module before the rating session, and the nontraining group did not. Interobserver reliability for training and nontraining was assessed by Siegel’s multirater kappa and the Z-test was used to test for significance.

Results There was a small, but significant difference in the interobserver reliability for displacement ratings in favor of the training group compared with the nontraining group. Ratings of radiographs and CT scans combined resulted in moderate agreement for both groups. The average sensitivity, specificity, and accuracy of diagnosing displacement of scaphoid fractures were, respectively, 83%, 85%, and 84% for the nontraining group and 87%, 86%, and 87% for the training group. Assuming a 5% prevalence of fracture displacement, the positive predictive value was 0.23 in the nontraining group and 0.25 in the training group. The negative predictive value was 0.99 in both groups.

Conclusions Our results suggest training can improve interobserver reliability and sensitivity, specificity and accuracy for the diagnosis of scaphoid fracture displacement, but the improvements are slight. These findings are encouraging for future research regarding interobserver variation and how to reduce it further.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To develop a new test of activities of daily living (ADLs) appropriate for the low-vision population: the Melbourne Low-Vision ADL Index (MLVAI).

METHODS. The MLVAI was designed as a desk-based clinical assessment, comprising 18 observed items on complex ADLs in part (a) and 9 questions on broad self-care ADLs in part (b). Each item was rated on a five-level descriptive scale from 0 to 4, based on independence, speed, and accuracy of performance. It was designed to be administered under standardized conditions with regard to the instructions, illumination, and working distances. The validity and reliability of the new MLVAI was determined for 122 subjects who were representative of the general low-vision population, in a cross-sectional study.

RESULTS. Two items were found to be redundant and were eliminated from the test. Thus, the final test comprised 25 items, with 100 being the highest possible score. Cronbach’s α indicated an internal reliability of 0.96, and an intraclass correlation coefficient indicated an overall reliability of 0.95. The SE of measurement was 4.5. According to Spearman’s correlation coefficient, the test–retest reliability was 0.94 (P < 0.001), and the interpractitioner reliability for five different pairs of practitioners was 0.90 or higher (P < 0.001). With regard to validity, there was a moderately high correlation with vision impairment (r = −0.68, P < 0.001). Using Rasch analysis, content validity was also demonstrated by good separation indexes (4.70 and 9.88) and high reliability scores (0.96 and 0.99) for the person and items parameters, respectively. Separate calculation of indexes and reliability scores for parts (a) and (b) indicated high content validity and reliability of each part. However, the separation indexes and reliability scores were higher for part (a) than for part (b). The correlation coefficient for part (a) and part (b) was 0.68.

CONCLUSIONS. The MLVAI is a highly valid and reliable standardized test of ADL performance for the general low-vision population. It may be used to assess patients with low vision and has the potential to be used as a measure of low-vision rehabilitation outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The Broberg and Morrey modification of the Mason classification of radial head fractures has substantial interobserver variation. This study used a large web-based collaborative of experienced orthopaedic surgeons to test the hypothesis that three-dimensional reconstructions of computed tomography (CT) scans improve the interobserver reliability of the classification of radial head fractures according to the Broberg and Morrey modification of the Mason classification.

Methods: Eighty-five orthopaedic surgeons evaluated twelve radial head fractures. They were randomly assigned to review either radiographs and two-dimensional CT scans or radiographs and three-dimensional CT images to determine the fracture classification, fracture characteristics, and treatment recommendations. The kappa multirater measure (κ) was calculated to estimate agreement between observers.

Results: Three-dimensional CT had moderate agreement and two-dimensional CT had fair agreement among observers for the Broberg and Morrey modification of the Mason classification, a difference that was significant. Observers assessed seven fracture characteristics, including fracture line, comminution, articular surface involvement, articular step or gap of ≥2 mm, central impaction, recognition of more than three fracture fragments, and fracture fragments too small to repair. There was a significant difference in kappa values between three-dimensional CT and two-dimensional CT for fracture fragments too small to repair, recognition of three fracture fragments, and central impaction. The difference between the other four fracture characteristics was not significant. Among treatment recommendations, there was fair agreement for both three-dimensional CT and two-dimensional CT.

Conclusions: Although three-dimensional CT led to some small but significant decreases in interobserver variation, there is still considerable disagreement regarding classification and characterization of radial head fractures. Three-dimensional CT may be insufficient to optimize interobserver agreement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite the hackneyed expression that ‘judges should interpret the law and not make it’, the fact remains that there is some scope within the separation of powers doctrine for the courts to develop the common law incrementally. To this extent, the courts can effectively legislate, but only to this limited extent if they are to respect the separation of powers doctrine. On occasion, however, the courts have usurped the power entrusted to Parliament, and particularly so in instances where a strict application of the existing law would lead to results that offend their personal notions of what is fair and just. When this occurs, the natural consequence is that lawyers, academics and the public in general lose respect for both the judges involved as well as the adversarial system of criminal justice. In order to illustrate this point, attention will focus on the case of Thabo Meli v United Kingdom in which the Privy Council, mistakenly believing that it could not reach its desired outcome through a strict application of the common law rule of temporal coincidence, emasculated the rule beyond recognition in order to convict the accused. Moreover, the discussion to follow will demonstrate that not only was the court wrong in its belief that the case involved the doctrine of temporal coincidence, but the same result would have been achieved had the Council correctly identified the issue as one of legal causation and correctly applied the principles relating thereto.